• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 19:12:45 on October 26, 2000

    Entry number 50939

    keyword=End_of_Run_2060
    ****************************
     Run Number: 2060
    End of Run Comment:
    Tar=dum-15cm,Type=Elastic,Pmom=0.76960,Emom=2.3793,Ene=2.386,Angle_e=18.586,Angle_h=79.965
    
    Time of run = 14.29235 min
    Av. current (on 3x) = 5.2783481 uA
    Av. current (on 1x) = 5.2319363 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    4.4866  |    4.5264  |    4.5517
    up-down    (mC)|    0.1213  |    0.0569  |    0.0996
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |     11981.0 /mC  |   63.240 Hz  |     54231  |     1   |     12087.3 /mC
        2      |    642310.4 /mC  |   16.952 Hz  |   2907354  |   200   |    648008.3 /mC
        3      |      3683.5 /mC  |   19.443 Hz  |     16673  |     1   |      3716.2 /mC
        4      |      3165.7 /mC  |   16.709 Hz  |     14329  |     1   |      3193.7 /mC
        5      |      1925.8 /mC  |   10.165 Hz  |      8717  |     1   |      1942.9 /mC
        output                       104.676 Hz
    Av. deadtime from accepted triggers = 0.1726
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  0.0  Hz     |    0.0 Hz   |  63.240123 Hz
        2      |  0.0  Hz     |    0.0 Hz   |  3390.3381 Hz
        3      |  19.260225  Hz     |    19.641232 Hz   |  19.442802 Hz
        4      |  16.384755  Hz     |    17.006519 Hz   |  16.709405 Hz
        5      |  0.0  Hz     |    0.0 Hz   |  10.165111 Hz
        output |  0.0  Hz   |    0.0 Hz |   104.676 Hz
    Accepted triggers  =  89764.00000
     Time of run = 14.29235 min
     Time of run h- = 7.065918 min
     Time of run h+ = 7.065511 min
     1-(sum of time hel + and -)/( run time) = 1.1259e-02
    Rate of Left Arm Pulser for electronic DT  = 10.172108
    Rate of Right Arm Pulser for electronic DT  = 10.172108
    Rate of Left Arm Pulser&trig for electronic DT  = 10.170942
    Rate of Right Arm Pulser&trig for electronic DT  = 10.166278
    Left Arm Electronic DT  = 0.00011463946
    Right Arm Electronic DT  = 0.00057319729
    Rate of Left Strobe  = 3306.8261
    Rate of Right Arm Strobe  = 5085.9888
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.214624  Hz         |    0.0 Hz        |  11.21579 Hz
          -        |  0.0  Hz        |    11.21579 Hz       |  11.21579 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0022490         |   0.0022476         | 0.0045472     
       upstream 3x |   0.0022526         |   0.0022514         | 0.0045549     
       upstream 10x|   0.0022756         |   0.0022744         | 0.0046015     
      downstream   |   0.0021890         |   0.0021876         | 0.0044259    
     downstream 3x |   0.0022244         |   0.0022233         | 0.0044980    
     downstream 10x|   0.0022264         |   0.0022252         | 0.0045019    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -3.11346350e-04 
       upstream 3x |   -2.66429840e-04 
       upstream 10x|   -2.63736260e-04 
      downstream   |   -3.19883010e-04 
     downstream 3x |   -2.47318840e-04 
     downstream 10x|   -2.69566000e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 2060 at Thu Oct 26 19:12:34 EDT 2000
    Right Arm D1 momentum                    : 2.3793
    Right Arm arm angle                      : 18.5865
    Left Arm D1 momentum                      : 0.769601
    Left Arm arm angle                        : 79.9649
    Tiefenbach Hall A energy                : 2385.96
    Right Arm arm mispointing (HPT)          : -0.958579
    Left Arm arm mispointing (HPT)            : 5.9797
    Right Arm Q1 power supply current        : 1789.09
    Right Arm Q1 momentum                    : 2.37932
    Right Arm Q1 gauss meter                 : 0.04491
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1023.99
    Right Arm Q2 momentum                    : 2.37935
    Right Arm Q2 gauss meter                 : -0.5388
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 836.231
    Right Arm D1 momentum                    : 2.3793
    Right Arm D1 NMR                         : 0.882929
    Right Arm Q3 power supply current        : 946.759
    Right Arm Q3 momentum                    : 2.37934
    Right Arm Q3 gauss meter                 : -0.4245
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 578.795
    Left Arm Q1 momentum                      : 0.769335
    Left Arm Q1 gauss meter                   : -0.04906
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 331.371
    Left Arm Q2 momentum                      : 0.769556
    Left Arm Q2 gauss meter                   : 0.17537
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 256.591
    Left Arm D1 momentum                      : 0.769602
    Left Arm D1 NMR                           : 0.284988
    Left Arm Q3 power supply current          : 306.491
    Left Arm Q3 momentum                      : 0.769849
    Left Arm Q3 gauss meter                   : -0.15253
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 5.38896
    Current on Unser monitor                : 6.07586
    Current on Upstream bcm                 : 5.39133
    Current on Downstream bcm               : 5.3866
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 5.37
    MBSY1c Hall A Beam energy               : 2391.67
    MBSY1c magnet current (amp)             : 99.5365
    MBSY1c Bdl                              : 596843
    MBSY3c Hall C Beam energy               : 826.013
    Tiefenbach Hall A energy                : 2385.96
    Tiefenbach Hall C energy                : 823.934
    Delta(E)/E width (MV_AI_DXWID)          : 4.34319
    IPM1C12.XPOS                            : 0.0793718
    IPM1H04A.XPOS                           : -0.721042
    IPM1H04A.YPOS                           : -1.5302
    IPM1H04B.XPOS                           : 0.0574304
    IPM1H04B.YPOS                           : -0.0971801
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617236
     HacR_HPM_LVDT:VALr                     : -1636
     HacR_VPM_LVDT:VALr                     : -190
     HacR_HPE1313A:0_Ch58                   : -0.535645
     HacR_HPE1313A:0_Ch55                   : 22.3633
     HacR_HPE1313A:0_Ch54                   : -0.814941
     HacR_alignROLL                         : -0.334453
     HacR_alignPITCH                        : -0.0197865
     HacR_alignHPT                          : -0.958331
     HacL_HPM_LVDT:VALr                     : -8814
     HacL_VPM_LVDT:VALr                     : 770
     HacL_HPE1313A:0_Ch58                   : -0.330078
     HacL_HPE1313A:0_Ch55                   : 23.9258
     HacL_HPE1313A:0_Ch54                   : -0.237305
     HacL_alignROLL                         : 0.123942
     HacL_alignPITCH                        : 0.0497857
     HacL_alignHPT                          : 5.9819
    haBDSPOS                                 : 1.72636e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 40.5
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 23.98
    haH2_P_Exhaust_R                         : 24.05
    haH2_P_Fill_Bottle_R                     : 23.76
    haH2_DP_Fill_Exhaust_R                   : -0.0033
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.515
    haSC200_6_Sensor_1_R                     : 242.45
    haSC200_6_Sensor_2_R                     : 28.22
    haSC200_6_Sensor_3_R                     : 3.27
    haSC200_6_Sensor_4_R                     : 37.85
    haHe_Omega_DPG_Sensor_R                  : -0.028
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.06
    haITC502_4_Sensor_1_R                    : 137.3
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 57.3
    haITC502_5_Sensor_1_R                    : 86.51
    haITC502_5_Sensor_2_R                    : 78.11
    haITC502_5_Sensor_3_R                    : 159.9
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 26.05
    Right Arm Arm Collimator                 : 0.614941
    Left Arm Arm Collimator                   : 0.617236
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 70
    Laser power  Hall A                      : 63