    User name adev

    Log entry time 00:44:57 on October 27, 2000

    Entry number 50976

    keyword=End_of_Run_2070
    ****************************
     Run Number: 2070
    End of Run Comment:
    Tar=dum-15cm,Type=Elastic,Pmom=1.19680,Emom=1.91270,Ene=2.386,Angle_e=29.748,Angle_h=52.469, Junk
    
    
    Time of run = 0.2030599 min
    Av. current (on 3x) = 29.506893 uA
    Av. current (on 1x) = 29.4084 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    0.3583  |    0.3595  |    0.3604
    up-down    (mC)|    0.0070  |    0.0059  |    0.0079
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |     26820.6 /mC  |  791.392 Hz  |      9642  |     1   |     26910.4 /mC
        2      |    563427.0 /mC  |   83.125 Hz  |    202552  |   200   |    565314.0 /mC
        3      |      3735.7 /mC  |  110.230 Hz  |      1343  |     1   |      3748.3 /mC
        4      |      3007.0 /mC  |   88.726 Hz  |      1081  |     1   |      3017.0 /mC
        5      |      2069.5 /mC  |   61.066 Hz  |       744  |     1   |      2076.5 /mC
        output                       887.833 Hz
    Av. deadtime from accepted triggers = 0.2175
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  0.0  Hz     |    0.0 Hz   |  791.3921 Hz
        2      |  0.0  Hz     |    0.0 Hz   |  16624.979 Hz
        3      |  106.42836  Hz     |    114.63185 Hz   |  110.2302 Hz
        4      |  92.33738  Hz     |    85.389034 Hz   |  88.725872 Hz
        5      |  0.0  Hz     |    0.0 Hz   |  61.065725 Hz
        output |  0.0  Hz   |    0.0 Hz |   887.833 Hz
    Accepted triggers  =  10817.00000
     Time of run = 0.2030599 min
     Time of run h- = 0.099739583 min
     Time of run h+ = 0.10053711 min
     1-(sum of time hel + and -)/( run time) = 1.3706e-02
    Rate of Left Arm Pulser for electronic DT  = 10.177621
    Rate of Right Arm Pulser for electronic DT  = 10.177621
    Rate of Left Arm Pulser&trig for electronic DT  = 10.177621
    Rate of Right Arm Pulser&trig for electronic DT  = 10.177621
    Left Arm Electronic DT  = 0.0
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 19361.282
    Rate of Right Arm Strobe  = 26098.785
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.080474  Hz         |    0.0 Hz        |  11.080474 Hz
          -        |  0.0  Hz        |    11.080474 Hz       |  11.162552 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0001791         |   0.0001779         | 0.0003618     
       upstream 3x |   0.0001794         |   0.0001782         | 0.0003625     
       upstream 10x|   0.0001804         |   0.0001792         | 0.0003644     
      downstream   |   0.0001756         |   0.0001744         | 0.0003548    
     downstream 3x |   0.0001765         |   0.0001753         | 0.0003566    
     downstream 10x|   0.0001765         |   0.0001753         | 0.0003565    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -3.36134450e-03 
       upstream 3x |   -3.35570470e-03 
       upstream 10x|   -3.33704120e-03 
      downstream   |   -3.42857140e-03 
     downstream 3x |   -3.41102900e-03 
     downstream 10x|   -3.41102900e-03 
     
    
    ****************************
    End-of-run EPICS data for Run Number 2070 at Fri Oct 27 00:44:47 EDT 2000
    Right Arm D1 momentum                    : 1.9127
    Right Arm arm angle                      : 29.7477
    Left Arm D1 momentum                      : 1.19679
    Left Arm arm angle                        : 52.4692
    Tiefenbach Hall A energy                : 2385.96
    Right Arm arm mispointing (HPT)          : 2.30516
    Left Arm arm mispointing (HPT)            : 4.96825
    Right Arm Q1 power supply current        : 1438.32
    Right Arm Q1 momentum                    : 1.91283
    Right Arm Q1 gauss meter                 : 0.03621
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 823.228
    Right Arm Q2 momentum                    : 1.91263
    Right Arm Q2 gauss meter                 : -0.4334
    Right Arm Q2 power supply polarity       : 1
    Right Arm D1 power supply current        : 661.313
    Right Arm D1 momentum                    : 1.9127
    Right Arm D1 NMR                         : 0.709779
    Right Arm Q3 power supply current        : 761.047
    Right Arm Q3 momentum                    : 1.91262
    Right Arm Q3 gauss meter                 : -0.3415
    Right Arm Q3 power supply polarity       : 0
    Left Arm Q1 power supply current          : 900.095
    Left Arm Q1 momentum                      : 1.19641
    Left Arm Q1 gauss meter                   : -0.0762
    Left Arm Q1 power supply polarity         : 0
    Left Arm Q2 power supply current          : 515.306
    Left Arm Q2 momentum                      : 1.19672
    Left Arm Q2 gauss meter                   : 0.2724
    Left Arm Q2 power supply polarity         : 1
    Left Arm D1 power supply current          : 399.985
    Left Arm D1 momentum                      : 1.19679
    Left Arm D1 NMR                           : 0.443034
    Left Arm Q3 power supply current          : 476.473
    Left Arm Q3 momentum                      : 1.19681
    Left Arm Q3 gauss meter                   : -0.2374
    Left Arm Q3 power supply polarity         : 1
    Average current of the two cavities     : 29.9469
    Current on Unser monitor                : 30.8779
    Current on Upstream bcm                 : 29.9836
    Current on Downstream bcm               : 29.9102
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 29.9967
    MBSY1c Hall A Beam energy               : 2391.67
    MBSY1c magnet current (amp)             : 99.5365
    MBSY1c Bdl                              : 596843
    MBSY3c Hall C Beam energy               : 826.614
    Tiefenbach Hall A energy                : 2385.96
    Tiefenbach Hall C energy                : 824.532
    Delta(E)/E width (MV_AI_DXWID)          : 4.33746
    IPM1C12.XPOS                            : 0.119777
    IPM1H04A.XPOS                           : -0.747779
    IPM1H04A.YPOS                           : -1.59924
    IPM1H04B.XPOS                           : 0.00785065
    IPM1H04B.YPOS                           : -0.173361
    Right Arm Arm Collimator                 : 0.615039
    Left Arm Arm Collimator                   : 0.617236
     HacR_HPM_LVDT:VALr                     : -4615
     HacR_VPM_LVDT:VALr                     : -203
     HacR_HPE1313A:0_Ch58                   : -0.561035
     HacR_HPE1313A:0_Ch55                   : 22.4121
     HacR_HPE1313A:0_Ch54                   : -0.737793
     HacR_alignROLL                         : -0.257499
     HacR_alignPITCH                        : 0.00393507
     HacR_alignHPT                          : 2.30544
     HacL_HPM_LVDT:VALr                     : -7798
     HacL_VPM_LVDT:VALr                     : -576
     HacL_HPE1313A:0_Ch58                   : -0.306641
     HacL_HPE1313A:0_Ch55                   : 23.9258
     HacL_HPE1313A:0_Ch54                   : -0.341309
     HacL_alignROLL                         : 0.0290187
     HacL_alignPITCH                        : 0.0291905
     HacL_alignHPT                          : 4.9662
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62.5
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 21.69
    haH2_P_Exhaust_R                         : 21.58
    haH2_P_Fill_Bottle_R                     : 23.56
    haH2_DP_Fill_Exhaust_R                   : -0.0033
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.45
    haSC200_6_Sensor_1_R                     : 242.65
    haSC200_6_Sensor_2_R                     : 27.35
    haSC200_6_Sensor_3_R                     : 3.36
    haSC200_6_Sensor_4_R                     : 37.88
    haHe_Omega_DPG_Sensor_R                  : -0.028
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 18.99
    haITC502_2_Sensor_3_R                    : 19.11
    haITC502_4_Sensor_1_R                    : 124.8
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 58.6
    haITC502_5_Sensor_1_R                    : 78.75
    haITC502_5_Sensor_2_R                    : 71.1
    haITC502_5_Sensor_3_R                    : 152.2
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 25.72
    Right Arm Arm Collimator                 : 0.61499
    Left Arm Arm Collimator                   : 0.617285
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 1651.6
    Wien field                               : 48.828
    Laser attenuation Hall A                 : 185
    Laser power  Hall A                      : 63