Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 05:30:09 on October 27, 2000
Entry number 51006
keyword=Start_Run_2082_Tar=LH2-15cm,Type=Elastic,Pmom=1.7961,Emom=1.2100,Ene=2.386,Angle_e=46.948,Angle_h=29.472
Beginning-of-run EPICS data for Run Number 2082 at Fri Oct 27 05:29:54 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=2,ps2=200,ps3=4,ps4=20,ps5=1,ps6=65535,ps8=65000
Right Arm Q1 power supply current : 909.825
Right Arm Q1 momentum : 1.20998
Right Arm Q1 gauss meter : 0.02303
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 520.664
Right Arm Q2 momentum : 1.20981
Right Arm Q2 gauss meter : -0.2745
Right Arm Q2 power supply polarity : 1
Right Arm D1 power supply current : 413.244
Right Arm D1 momentum : 1.21
Right Arm D1 NMR : 0.449016
Right Arm Q3 power supply current : 481.475
Right Arm Q3 momentum : 1.21001
Right Arm Q3 gauss meter : -0.2162
Right Arm Q3 power supply polarity : 0
Left Arm Q1 power supply current : 1351.24
Left Arm Q1 momentum : 1.79608
Left Arm Q1 gauss meter : -0.11438
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 773.386
Left Arm Q2 momentum : 1.79607
Left Arm Q2 gauss meter : 0.4083
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 605.832
Left Arm D1 momentum : 1.79611
Left Arm D1 NMR : 0.664669
Left Arm Q3 power supply current : 715.085
Left Arm Q3 momentum : 1.79616
Left Arm Q3 gauss meter : -0.3565
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 6.11531
Current on Unser monitor : 6.74832
Current on Upstream bcm : 6.11797
Current on Downstream bcm : 6.11265
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 7.95653
Beam energy : 2391.67
MBSY1c magnet current (amp) : 99.5365
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.5
haSC200_6_Sensor_2_R : 27.22
haSC200_6_Sensor_3_R : 3.29
haSC200_6_Sensor_4_R : 37.9
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 123
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 57
haITC502_5_Sensor_1_R : 77.21
haITC502_5_Sensor_2_R : 69.68
haITC502_5_Sensor_3_R : 150.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 25.7
Right Arm Arm Collimator : 0.61499
Left Arm Arm Collimator : 0.617188
HacR_HPM_LVDT:VALr : -4889
HacR_VPM_LVDT:VALr : 65
HacR_HPE1313A:0_Ch58 : -0.532715
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.887207
HacR_alignROLL : -0.406361
HacR_alignPITCH : -0.0220972
HacR_alignHPT : 2.64363
HacL_HPM_LVDT:VALr : -6969
HacL_VPM_LVDT:VALr : 949
HacL_HPE1313A:0_Ch58 : -0.17334
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.230957
HacL_alignROLL : 0.129244
HacL_alignPITCH : -0.0903938
HacL_alignHPT : 4.0045
Right Arm Angle Floor Angle : 46.5
Right Arm Angle Vernier : 46.7
Right Arm Scattering Angle : 46.9483
Left Arm Angle Floor Angle : 29.5
Left Arm Angle Vernier : 31
Left Arm Scattering Angle : 29.4725
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 75
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88