    keyword=Harp scans after Arc -energy measurement

    Harp scans after Arc -energy measurement
    ______________________________________

    We made harp scans after recovery from arc-energy measurement (Dispersive mode)
    Scan #1151
    ***************************************************************
    Uncorrected Corrected Sigma Base
    position position Width Width
    Scanner #5 4ax: -1243.0um -1163.0um 158.0um
    Scanner #5 4ay: 1146.00um 1236.00um 25.7um
    Scanner #6 4bx: 231.00um 31.00um 158.0um
    Scanner #6 4by: 511.00um 321.00um 54.3um

    ***************************************************************
    Uncorrected Corrected
    position position
    Target x pos : 496.42 um 246.00 um (+ for beam left)
    Target y pos : 396.66 um 156.24 um (+ for too high)
    Beam h angle: -0.24 mrad -0.19 mrad (+ for clockwise)
    Beam v slope: -0.10 mrad -0.15 mrad (+ for ascending slope)
    ***************************************************************