User name adev
Log entry time 13:39:33 on October 28, 2000
Entry number 51218
keyword=Start_Run_2165_Tar=9foil-12C,Type=Optics,Pmom=1.0,Emom=1.0,Ene=2.386,Angle_e=38.714,Angle_h=38.698
Beginning-of-run EPICS data for Run Number 2165 at Sat Oct 28 13:39:19 EDT 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=84,ps3=1,ps4=1,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018889
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.553
Right Arm Q2 momentum : 1.00043
Right Arm Q2 gauss meter : 0.2264
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 341.49
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.92
Right Arm Q3 momentum : 1.00003
Right Arm Q3 gauss meter : 0.17839
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 752.15
Left Arm Q1 momentum : 0.999759
Left Arm Q1 gauss meter : -0.06365
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 430.626
Left Arm Q2 momentum : 1.00006
Left Arm Q2 gauss meter : 0.2277
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 334.58
Left Arm D1 momentum : 0.999998
Left Arm D1 NMR : 0.37023
Left Arm Q3 power supply current : 398.136
Left Arm Q3 momentum : 1.00004
Left Arm Q3 gauss meter : -0.19862
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 40.1838
Current on Unser monitor : 40.3537
Current on Upstream bcm : 39.8459
Current on Downstream bcm : 39.8242
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 57.7609
Beam energy : 2391.67
MBSY1c magnet current (amp) : 99.5365
haBDSPOS : 2.50445e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.66
haSC200_6_Sensor_2_R : 27.42
haSC200_6_Sensor_3_R : 3.47
haSC200_6_Sensor_4_R : 38.1
haHe_Omega_DPG_Sensor_R : -0.027
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 124.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 62
haITC502_5_Sensor_1_R : 77.39
haITC502_5_Sensor_2_R : 69.84
haITC502_5_Sensor_3_R : 151.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 25.88
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868652
HacR_HPM_LVDT:VALr : -4336
HacR_VPM_LVDT:VALr : 348
HacR_HPE1313A:0_Ch58 : -0.521973
HacR_HPE1313A:0_Ch55 : 22.3633
HacR_HPE1313A:0_Ch54 : -0.928223
HacR_alignROLL : -0.448807
HacR_alignPITCH : -0.0319047
HacR_alignHPT : 2.07724
HacL_HPM_LVDT:VALr : -7552
HacL_VPM_LVDT:VALr : 300
HacL_HPE1313A:0_Ch58 : -0.194824
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.212402
HacL_alignROLL : 0.145293
HacL_alignPITCH : -0.0717619
HacL_alignHPT : 4.63552
Right Arm Angle Floor Angle : 38.5
Right Arm Angle Vernier : 5.5
Right Arm Scattering Angle : 38.7146
Left Arm Angle Floor Angle : 39
Left Arm Angle Vernier : -15.9
Left Arm Scattering Angle : 38.698
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 249
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88