User name adev
Log entry time 14:26:28 on October 29, 2000
Entry number 51323
keyword=Start_Run_2210_Tar=LH2-15cm,Type=Elastic,Pmom=1.9203,Emom=1.200,Ene=2.386,Angle_e=29.53,Angle_h=52.9
Beginning-of-run EPICS data for Run Number 2210 at Sun Oct 29 14:26:14 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=80,ps3=1,ps4=1,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 1326.6
Right Arm Q1 momentum : 1.76426
Right Arm Q1 gauss meter : -0.03317
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 759.19
Right Arm Q2 momentum : 1.76405
Right Arm Q2 gauss meter : 0.3992
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 370.062
Right Arm D1 momentum : 1.07848
Right Arm D1 NMR : 0.400213
Right Arm Q3 power supply current : 701.964
Right Arm Q3 momentum : 1.76413
Right Arm Q3 gauss meter : 0.3149
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1444.62
Left Arm Q1 momentum : 1.9202
Left Arm Q1 gauss meter : 0.12291
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 826.867
Left Arm Q2 momentum : 1.92027
Left Arm Q2 gauss meter : -0.4359
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 650.611
Left Arm D1 momentum : 1.92029
Left Arm D1 NMR : 0.710591
Left Arm Q3 power supply current : 764.484
Left Arm Q3 momentum : 1.92024
Left Arm Q3 gauss meter : 0.3817
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 11.1019
Current on Unser monitor : 11.5877
Current on Upstream bcm : 11.1192
Current on Downstream bcm : 10.9674
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 30.9082
Beam energy : 2391.67
MBSY1c magnet current (amp) : 99.5365
haBDSPOS : 5.35401e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 243.03
haSC200_6_Sensor_2_R : 27.09
haSC200_6_Sensor_3_R : 3.67
haSC200_6_Sensor_4_R : 38.21
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 121.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 55.8
haITC502_5_Sensor_1_R : 75.92
haITC502_5_Sensor_2_R : 68.49
haITC502_5_Sensor_3_R : 147.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 25.48
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868555
HacR_HPM_LVDT:VALr : -1143
HacR_VPM_LVDT:VALr : -194
HacR_HPE1313A:0_Ch58 : -0.54834
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.757324
HacR_alignROLL : -0.275678
HacR_alignPITCH : -0.00780079
HacR_alignHPT : -1.57132
HacL_HPM_LVDT:VALr : -7347
HacL_VPM_LVDT:VALr : 714
HacL_HPE1313A:0_Ch58 : -0.17627
HacL_HPE1313A:0_Ch55 : 24.0234
HacL_HPE1313A:0_Ch54 : -0.227539
HacL_alignROLL : 0.132181
HacL_alignPITCH : -0.0876307
HacL_alignHPT : 4.42434
Right Arm Angle Floor Angle : 30.5
Right Arm Angle Vernier : -20.3
Right Arm Scattering Angle : 30.5906
Left Arm Angle Floor Angle : 29.5
Left Arm Angle Vernier : 41.5
Left Arm Scattering Angle : 29.5302
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1651.6
Wien field : 48.828
Laser attenuation Hall A : 121
Laser power Hall A : 63
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88