    keyword=magnitude of problem

    Below is a plot of the left-side-measured tc variable (standard sign
    convention, i.e. no Templon minus sign applied). The fit shows
    50 counts/ns of randoms. Peak contains 800 counts, so this means
    there are 800/50 = 16 ns of coincidence gate piled into these two
    channels. The flat part of the spectrum is 54 ns. So of 70 ns total
    coinc gate, 16 ns is potentially junk (23%).
    .
    Next replay will be to inspect adc,tdc spectra based on gates on various parts
    of this tc spectrum. stay tuned.